Cooler Master TPC 812 Performance Cooler Review
Author: Dennis Garcia
Published: Sunday, April 15, 2012
Benchmarks
The Cooler Master TPC 812 is designed for Intel Socket LGA2011 / 1366 / 1156 / 1155 / 775 and Athlon 64 processors. Here is an overview of the system and testing methodology.
The system as it was tested
Asus Rampage IV Extreme Intel X79 Chipset
Intel Core i7 3960x (3.3Ghz) Hex Core 6 x 256KB L2 Cache 15MB L3 Cache
Cooler Master TPC 812
Danger Den M6
The CPUID System Monitor was used to obtain and record system temperature data and being that this is a quad core processor we need something that will work across all of the cores at once. For this task we're using a new version of Prime95 (p95v255a) that will allow you to spawn (n) instances to test with.
Intel Core i7 3960x (3.3Ghz) Hex Core 6 x 256KB L2 Cache 15MB L3 Cache
Cooler Master TPC 812
Danger Den M6
The CPUID System Monitor was used to obtain and record system temperature data and being that this is a quad core processor we need something that will work across all of the cores at once. For this task we're using a new version of Prime95 (p95v255a) that will allow you to spawn (n) instances to test with.
Editors note: Even though the Windows 7 task manager reported 100% processor usage we could never attain a 100% of the rated heat output as documented by Intel (see below) when using Prime95 as a basis for that heat production. Knowing this we ran the stress test until the maximum temperature was attainted and stabilized.
Other things to consider when judging software induced heat output.
a) Clock throttling by the processor at high temperatures.
b) Normal software isn't designed to produce maximum heat output.
c) Variances of cooling temperature.
d) Variances in CPU load.
e) Inaccuracies in thermal diode readouts.
Of course the list goes on..
Our testing methodology is aimed to provide a real world look into this heatsink given the test system provided.
Other things to consider when judging software induced heat output.
a) Clock throttling by the processor at high temperatures.
b) Normal software isn't designed to produce maximum heat output.
c) Variances of cooling temperature.
d) Variances in CPU load.
e) Inaccuracies in thermal diode readouts.
Of course the list goes on..
Our testing methodology is aimed to provide a real world look into this heatsink given the test system provided.
Default Speed
A C/W rating can quickly be calculated using this formula.
C/W = (CPU temp - Ambient temp)/(Variance(%) * CPU Watts)
Allowed variance for this test = 85%
CPU Watts = 130W
0.26C/W = (52C - 23C)/(.85(130W))
C/W = (CPU temp - Ambient temp)/(Variance(%) * CPU Watts)
Allowed variance for this test = 85%
CPU Watts = 130W
0.26C/W = (52C - 23C)/(.85(130W))
Overclocked
For this next test the CPU speed was cranked up to 4.7Ghz and the test was re-run.
To calculate a new C/W rating for this test we will need to factor in the increased processor wattage. The formula and constants for this are listed below.
ocC/W = dCPU Watts * (ocMhz / dMhz) * (ocVcore / dVcore)2
ocMhz = 4700
dMhz = 3300
ocVcore = 1.35
dVcore = 1.2
The variance still applies for our C/W calculation
Allowed variance for this test = 85%
CPU Watts = 234W
0.19 C/W = (60C - 23C)/(.85(234W))
ocC/W = dCPU Watts * (ocMhz / dMhz) * (ocVcore / dVcore)2
ocMhz = 4700
dMhz = 3300
ocVcore = 1.35
dVcore = 1.2
The variance still applies for our C/W calculation
Allowed variance for this test = 85%
CPU Watts = 234W
0.19 C/W = (60C - 23C)/(.85(234W))
Benchmark Conclusion
In our heatsink and waterblock tests we don't really focus on overall load temperatures but rather how well the product can remove heat given a specified heat load. Since this is a real world testing method we need to take into consideration real world variables and estimate tolerances. This is why we normally only apply 85% of the total wattage output to our heat calculations.
The resulting C/W number is used to rate how efficient a heatsink or waterblock is based on the given heat load. These numbers can be used to determine heat capacity, the larger the difference the less efficient the heatsink is. (aka not good for overclocking)
We clearly have a heatsink that can handle some heat and looking over some of our past heatsinks we can clearly see the vapor chamber in action. Normally the C/W difference between the Normal and OC tests is minor and often dependent on us finding the thermal limit of the heatsink however in the case of the TPC 812 we have a complete reversal of C/W which tells us that the heatsink has gotten more efficient with a higher heat load.
Keep in mind these calculations are provided for demonstration purposes only and may not reflect the actual lab tested C/W rating, but we're pretty close.
The resulting C/W number is used to rate how efficient a heatsink or waterblock is based on the given heat load. These numbers can be used to determine heat capacity, the larger the difference the less efficient the heatsink is. (aka not good for overclocking)
We clearly have a heatsink that can handle some heat and looking over some of our past heatsinks we can clearly see the vapor chamber in action. Normally the C/W difference between the Normal and OC tests is minor and often dependent on us finding the thermal limit of the heatsink however in the case of the TPC 812 we have a complete reversal of C/W which tells us that the heatsink has gotten more efficient with a higher heat load.
Keep in mind these calculations are provided for demonstration purposes only and may not reflect the actual lab tested C/W rating, but we're pretty close.